Yaskawa Inverter | J1000 | Three-phase 200 V | 0.75 kW | ND 6 A 1.1 kW | HD 5 A 0.75 kW | IP20 Finless
40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
Input accessories (4)
Braking accessories (1)
10% ED: 120 s cycle time (t) and 12 s switch on time (ton)40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
Braking unit | Quantity | Braking resistor | |||
---|---|---|---|---|---|
40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
built-in | - | RH-0260W135 | 1 | RH-0260W135 | 1 |
Braking unit | Quantity | Braking resistor | |||
---|---|---|---|---|---|
40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
built-in | - | RH-0260W135 | 1 | RH-0260W135 | 1 |
Interface modules (6)
Input parameters | |
---|---|
AC Input power supply | Three-phase 200 to 240 V +10%/-15% |
Output parameters | |
Maximum applicable motor power (HD), kW | 0.75 |
Maximum applicable motor power (ND), kW | 1.1 |
Rated output current (HD), A (Carrier frequency is set to 10 kHz) | 5.0 |
Rated output current (ND), A (Carrier frequency is set to 2 kHz) | 6.0 |
Overload tolerance (HD), A | 150% for 60 s |
Overload tolerance (ND), A | 120% for 60 s |
Motor type | Induction motor |
Torque control | Not available |
Maximum output frequency, Hz | 400 |
Control methods | Open loop V/f |
Rated output power (HD), kVA (Carrier frequency is set to 10 kHz) | 1.9 |
Rated output power (ND), kVA (Carrier frequency is set to 2 kHz) | 2.3 |
Speed Control Range | |
V/f control (V/f) | 1:20 |
Inputs, outputs, interfaces | |
Analog inputs | 1 |
Analog outputs | 1 |
Digital inputs | 5 |
Digital outputs | 1 |
Dimensions and weight | |
H - Height, mm | 128 |
W - Width, mm | 68 |
D - Depth, mm | 71 |
Weight, kg | 0.7 |
W1, mm | 56 |
H1, mm | 118 |
H2, mm | 5 |
D2, mm | 62.5 |
t1, mm | 3 |
Enclosure and design | |
Enclosure | IP20 (Cold plate) |
Braking transistor (module) | Built-in |
Motor thermal protection | Standard |
Built-in EMC filter | No |
Environmental parameters and standards | |
Ambient temperature (min) | -10 °C |
Ambient temperature (max) | 40 °C |
Ambient temperature (max) with derating | 50 °C |
Maximum humidity (non-condensing) | 95% |
Maximum altitude (without derating), m | 1 000 m |
Maximum altitude (with derating), m | 3 000 m |
Environmental specifications | Standard |
Standards compliance | cUL, CE, RoHS, UL, UKCA |
Dimensions and weight | |
---|---|
H - Height, mm | 128 |
W - Width, mm | 68 |
D - Depth, mm | 71 |
Weight, kg | 0.7 |
W1, mm | 56 |
H1, mm | 118 |
H2, mm | 5 |
D2, mm | 62.5 |
t1, mm | 3 |
Exterior and Mounting Dimensions
J1000 Dimensions
Standard Connection Diagram
J1000 Wiring
J1000 Installation (Three-Phase 200 V / 400 V Class)
J1000 Connecting Peripheral Devices
Model designation
J1000 Designation
CIMR-J |
---|
product series |
J1000 |
C | |
---|---|
region code |
|
С | Europe |
B | |
---|---|
voltage class |
|
B | single-phase 230 VAC |
2 | three-phase 230 VAC |
4 | three-phase 400 VAC |
A | |
---|---|
speci- fication |
|
A | standard |
0001 | |
---|---|
Inverter model No. |
|
0001 | 0,1-0,2 |
0002 | 0,2-0,4 |
0003 | 0,4 |
0004 | 0,75 |
0005 | 1,5 |
0006 | 0,75 |
0007 | 2,2 |
0009 | 3 |
0010 | 1,5 |
0011 | 3,7 |
0012 | 2,2 |
0020 | 4 |
B | |
---|---|
type |
|
B | standard fin IP20 without top cover |
J | finless IP20 |
A | |
---|---|
coating and protection |
|
A | standard |
A | |
---|---|
version |
|
A | version A |
CIMR-JC2A0006JAB
- Brand: Yaskawa
- Product Code: CIMR-JC2A0006JAB