Yaskawa Inverter | GA700 | Three-phase 380 V | 3.00 kW | ND 8.9 A 4.00 kW | HD 7.2 A 3.00 kW | IP20 | with EMC C3 Filter built-in
40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
Input accessories (3)
Optional mounting units (3)
Braking accessories (1)
10% ED: 120 s cycle time (t) and 12 s switch on time (ton)40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
Braking unit | Quantity | Braking resistor | |||
---|---|---|---|---|---|
40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
built-in | - | RH-0520W120 | 1 | RH-0520W120 | 1 |
Braking unit | Quantity | Braking resistor | |||
---|---|---|---|---|---|
40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
built-in | - | RH-0520W120 | 1 | RH-0520W120 | 1 |
Interface modules (4)
Optional input/output cards (4)
Optional PG-Interface cards (4)
Interface cards (14)
Output accessories (4)
Input parameters | |
---|---|
AC Input power supply | Three-phase 380 to 480 V |
DC Input power supply | 513 to 679 V |
Rated AC Power Supply Frequency, Hz | 50/60Hz |
Permitted AC Power Supply Voltage Fluctuation | -15/+10% |
Permitted AC Power Supply Frequency Fluctuation | +/- 5% |
Rated input current (ND), A | 11.7 |
Rated input current (HD), A | 8.9 |
Output parameters | |
Maximum applicable motor power (HD), kW | 3.0 |
Maximum applicable motor power (ND), kW | 4.0 |
Rated output current (HD), A (Carrier frequency is set to 8 kHz) | 7.2 |
Rated output current (ND), A (Carrier frequency is set to 2 kHz) | 8.9 |
Overload tolerance (HD), A | 150 % for 60 sec (one time each 10 minutes) |
Overload tolerance (ND), A | 110 % for 60 sec (one time each 10 minutes) |
Motor type | Induction motor (IM) Permanent magnet motor (IPM/SPM) Synchronous reluctance motor (SynRM) |
Maximum output frequency, Hz | AOLV, EZOLV: 120 Hz CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz V/f, OLV, OLV/PM: 590 Hz |
Control methods | V/f Control (V/f) V/f Control with Encoder (CL-V/f) Open Loop Vector (OLV) Closed Loop Vector (CLV) Advanced Open Loop Vector (AOLV) PM Open Loop Vector (OLV/PM) PM Advanced Open Loop Vector (AOLV/PM) PM Closed Loop Vector (CLV/PM) EZ Vector Control (EZOLV) |
Speed Control Range | |
V/f control (V/f) | 1:40 |
V/f Control with Encoder (CL-V/f) | 1:40 |
Open Loop Vector (OLV) | 1:200 |
Closed Loop Vector (CLV) | 1:1500 |
PM Open Loop Vector (OLV/PM) | 1:20 |
PM Advanced Open Loop Vector (AOLV/PM) | 1:100 |
PM Closed Loop Vector (CLV/PM) | 1:1500 |
EZ Vector Control (EZOLV) for IM/PM/SynRM | 1:100 |
Starting Torque | |
Starting Torque V/f Control | 150%/3 Hz |
V/f Control with Encoder (CL-V/f) | 150%/3 Hz |
Starting Torque Open Loop Vector(OLV) | 200%/0.3 Hz |
Closed Loop Vector (CLV) | 200%/0 min-1 (r/min) |
Advanced Open Loop Vector (AOLV) | 200%/0.3 Hz |
Starting Torque PM Open Loop Vector(OLV/PM) | 100%/5% speed |
Starting Torque PM Advanced Open Loop Vector(AOLV/PM) | 200%/0 min-1 (r/min) |
PM Closed Loop Vector (CLV/PM) | 200%/0 min-1 (r/min) |
Starting Torque EZ Vector Control(EZOLV) | 100%/1% speed |
Inputs, outputs, interfaces | |
Analog inputs | 3 (AI1 -10..+10 V/0..+10 V/4..20mA/0..20mA AI2 -10..+10 V/0..+10 V/4..20mA/0..20mA AI3 -10..+10 V/0..+10 V/4..20mA/0..20mA) |
Analog outputs | 2 (AO1 -10..+10 V/0..+10 V/4..20mA AO2 -10..+10 V/0..+10 V/4..20mA ) |
Digital inputs | 8 + 1 Pulse input (max. 32 kHz) |
Digital outputs | 1 x Relay Output (NO/NC) 3 x Relay Output 1 x Pulse train output (up to 32 kHz) |
Encoder interface | Available with optional PG card |
Communication on board | RS-485 (MEMOBUS/Modbus) |
Dimensions and weight | |
H - Height, mm | 260 |
W - Width, mm | 140 |
D - Depth, mm | 211 |
Weight, kg | 3.7 |
W1, mm | 102 |
W2, mm | 102 |
H1, mm | 248 |
H2, mm | 6 |
D1, mm | 138 |
D2, mm | 73 |
t1, mm | 1.6 |
d | M5 |
t2, mm | 5 |
Enclosure and design | |
DC reactor | Optional, external |
Enclosure | IP00/UL Open Type |
Braking transistor (module) | Built-in |
Cooling method | Fan cooled, 1 cooling fan |
Built-in EMC filter | Built in (IEC 61800-3, C3) |
Environmental parameters and standards | |
SIL (Safety Integrity Level) | SIL3 |
PL (Perfomance Level) | PL e |
Ambient temperature (min) | -10 °C |
Ambient temperature (max) | +50 °C |
Maximum humidity (non-condensing) | 95% |
Maximum altitude (without derating), m | 1000 |
Maximum altitude (with derating), m | 4000 |
Environmental specifications | Standard |
Standards compliance | cUL, CE, RoHS, UL, UKCA |
Dimensions and weight | |
---|---|
H - Height, mm | 260 |
W - Width, mm | 140 |
D - Depth, mm | 211 |
Weight, kg | 3.7 |
W1, mm | 102 |
W2, mm | 102 |
H1, mm | 248 |
H2, mm | 6 |
D1, mm | 138 |
D2, mm | 73 |
t1, mm | 1.6 |
d | M5 |
t2, mm | 5 |
Exterior and Mounting Dimensions
GA700 Dimensions
Catalogs | |||
---|---|---|---|
YEU INV GA700 RU v2 | russian | Yaskawa GA700 Inverter Series Catalog | |
YEU INV GA700 EN v8 | english | Yaskawa GA700 Inverter Series Catalog | |
YEU INV Range EN v11 | english | Yaskawa AC Drives Product Range Catalog | |
Technical Manuals | |||
SIEP C710617 05I | english | Yaskawa GA700 Inverter Series Technical Manual | |
EZZ024048 | english | Yaskawa GA700 Inverter Supplemental Technical Manual | |
Quick Start Guides | |||
TORP C710617 17D | russian | Yaskawa GA700 Inverter Series Initial Steps | |
TOEP C710617 17D | english | Yaskawa GA700 Inverter Series Initial Steps | |
Datasheets | |||
TOEP C710617 18B | english | Yaskawa GA700 Inverter Series Standards Compliance | |
CAD/EPLAN | |||
EPLAN_Makros_GA700.zip | english | EPLAN Makros for Yaskawa GA700 series inverters | |
CIPR_GA70C4009.zip | english | CAD file for Yaskawa GA700 series GA70C4009BBA AC Drive |
Standard Connection Diagram
GA700 Wiring
GA700 Drive Installation with a Built-in EMC Filter to Conform to the EMC Directive
GA700 Terminal Block Configuration
Model designation
GA700 Designation
GA70 |
---|
product series |
GA700 |
C | |
---|---|
region code | |
A | Japan |
B | China |
C | Europe |
D | India |
K | Korea |
T | Asia Singapore Taiwan |
U | Americas |
4 | |
---|---|
voltage class | |
2 | three phase 200 VAC |
4 | three phase 400 VAC |
004 | |
---|---|
model kW, HD | |
400 V | |
002 | 0.55 |
004 | 1.1 |
005 | 1.5 |
007 | 2.2 |
009 | 3.0 |
012 | 4.0 |
018 | 5.5 |
023 | 7.5 |
031 | 11 |
038 | 15 |
044 | 18.5 |
060 | 22 |
075 | 30 |
089 | 37 |
103 | 45 |
140 | 55 |
168 | 75 |
208 | 90 |
250 | 110 |
296 | 132 |
371 | 160 |
389 | 200 |
453 | 220 |
568 | 250 |
675 | 315 |
810 | 400 |
930 | 450 |
H11 | 500 |
H12 | 560 |
200 V | |
004 | 0.55 |
006 | 0.75 |
010 | 1.5 |
012 | 2.2 |
021 | 3.7 |
030 | 5.5 |
042 | 7.5 |
056 | 11 |
070 | 15 |
082 | 18.5 |
110 | 22 |
138 | 30 |
169 | 37 |
211 | 45 |
257 | 55 |
313 | 75 |
360 | 90 |
415 | 110 |
B | |
---|---|
EMC filter option | |
A | No built-in filter |
B | EMC filter built-in |
B | |
---|---|
enclosure | |
A | IP20 |
B | IP20 |
W | IP55 UL Type 12 Heatsink External Mounting |
A | |
---|---|
environmental spec | |
A | standard |
M | Moisture & Dust |
GA70C4009BBA
- Brand: Yaskawa
- Product Code: GA70C4009BBA