Yaskawa Inverter | J1000 | Three-phase 200 V | 0.4 kW | ND 3.5 A 0.75 kW | HD 3.0 A 0.4 kW | IP20 Finless
40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
Input accessories (4)
Braking accessories (1)
10% ED: 120 s cycle time (t) and 12 s switch on time (ton)40% ED: 120 s cycle time (t) and 48 s switch on time (ton)
| Braking unit | Quantity | Braking resistor | |||
|---|---|---|---|---|---|
| 40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
| built-in | - | RH-0260W270 | 1 | RH-0260W270 | 1 |
| Braking unit | Quantity | Braking resistor | |||
|---|---|---|---|---|---|
| 40% ED cycle | Quantity | 10% ED cycle | Quantity | ||
| built-in | - | RH-0260W270 | 1 | RH-0260W270 | 1 |
RH-0260W270
Braking resistor
Interface modules (6)
| Input parameters | |
|---|---|
| AC Input power supply | Three-phase 200 to 240 V +10%/-15% |
| Output parameters | |
| Maximum applicable motor power (HD), kW | 0.4 |
| Maximum applicable motor power (ND), kW | 0.75 |
| Rated output current (HD), A (Carrier frequency is set to 10 kHz) | 3.0 |
| Rated output current (ND), A (Carrier frequency is set to 2 kHz) | 3.5 |
| Overload tolerance (HD), A | 150% for 60 s |
| Overload tolerance (ND), A | 120% for 60 s |
| Motor type | Induction motor |
| Torque control | Not available |
| Maximum output frequency, Hz | 400 |
| Control methods | Open loop V/f |
| Rated output power (HD), kVA (Carrier frequency is set to 10 kHz) | 1.1 |
| Rated output power (ND), kVA (Carrier frequency is set to 2 kHz) | 1.3 |
| Speed Control Range | |
| V/f control (V/f) | 1:20 |
| Inputs, outputs, interfaces | |
| Analog inputs | 1 |
| Analog outputs | 1 |
| Digital inputs | 5 |
| Digital outputs | 1 |
| Dimensions and weight | |
| H - Height, mm | 128 |
| W - Width, mm | 68 |
| D - Depth, mm | 71 |
| Weight, kg | 0.7 |
| W1, mm | 56 |
| H1, mm | 118 |
| H2, mm | 5 |
| D2, mm | 62.5 |
| t1, mm | 3 |
| Enclosure and design | |
| Enclosure | IP20 (Cold plate) |
| Braking transistor (module) | Built-in |
| Motor thermal protection | Standard |
| Built-in EMC filter | No |
| Environmental parameters and standards | |
| Ambient temperature (min) | -10 °C |
| Ambient temperature (max) | 40 °C |
| Ambient temperature (max) with derating | 50 °C |
| Maximum humidity (non-condensing) | 95% |
| Maximum altitude (without derating), m | 1 000 m |
| Maximum altitude (with derating), m | 3 000 m |
| Environmental specifications | Standard |
| Standards compliance | cUL, CE, RoHS, UL, UKCA |
| Dimensions and weight | |
|---|---|
| H - Height, mm | 128 |
| W - Width, mm | 68 |
| D - Depth, mm | 71 |
| Weight, kg | 0.7 |
| W1, mm | 56 |
| H1, mm | 118 |
| H2, mm | 5 |
| D2, mm | 62.5 |
| t1, mm | 3 |
Exterior and Mounting Dimensions
J1000 Dimensions
Standard Connection Diagram
J1000 Wiring
J1000 Installation (Three-Phase 200 V / 400 V Class)
J1000 Connecting Peripheral Devices
Model designation
J1000 Designation
| CIMR-J |
|---|
| product series |
| J1000 |
| C | |
|---|---|
| region code |
|
| С | Europe |
| B | |
|---|---|
| voltage class |
|
| B | single-phase 230 VAC |
| 2 | three-phase 230 VAC |
| 4 | three-phase 400 VAC |
| A | |
|---|---|
| speci- fication |
|
| A | standard |
| 0001 | |
|---|---|
| Inverter model No. |
|
| 0001 | 0,1-0,2 |
| 0002 | 0,2-0,4 |
| 0003 | 0,4 |
| 0004 | 0,75 |
| 0005 | 1,5 |
| 0006 | 0,75 |
| 0007 | 2,2 |
| 0009 | 3 |
| 0010 | 1,5 |
| 0011 | 3,7 |
| 0012 | 2,2 |
| 0020 | 4 |
| B | |
|---|---|
| type |
|
| B | standard fin IP20 without top cover |
| J | finless IP20 |
| A | |
|---|---|
| coating and protection |
|
| A | standard |
| A | |
|---|---|
| version |
|
| A | version A |
CIMR-JC2A0004JAB
- Brand: Yaskawa
- Product Code: CIMR-JC2A0004JAB